Mixed Use Buildings (2024)

​In the AEC world, the terms “mixed use” and “mixed use building” are commonplace. Developers refer to new buildings that contain both office and retail spaces as mixed use projects. Architects and Engineers refer to a floor containing multiple occupancy types as mixed use. You’ll even hear AHJs drop the term mixed use in plan review meetings on occasion.

Colloquially, “mixed use” is meant to refer to a building or space that contains multiple occupancy types.

But did you know that other than parking garages, the building code has essentiallyno requirements pertaining to a mixed use building?

In fact, if you search for “mixed use” in the International Building Code (IBC), you won’t find any requirements related to building height, building area, construction type, fire-rated construction or means of egress. *

So why is “mixed use” a common term in the AEC world but not addressed in the codes? Long story short: there is a difference between use and occupancy in the IBC and people frequently confuse the two.We’ll do a full analysis of the differences between use and occupancy in a later article, but here is a simple way to understand the difference.

Mixed Use Buildings (1)

This is both a mixed use and mixed occupancy building (image courtesy of Brett VA).

Mixed Use Vs. Mixed Occupancy

The use of a space is a description of how the space will actually be used. This could be a broad, general description such as “office” or “conference room”, or it could be more specific, such as “visiting team locker room and shower.” The use of a space is helpful in determining (1) the occupancy classification and (2) the appropriate occupant load for a space.

On the other hand, the occupancy classification of a space is 1 of 10 categories (plus sub categories) in Chapter 3 of the IBC. These occupancies are:

  • Assembly – Groups (A-1, A-2, A-3, A-4, A-5)
  • Business – Group B
  • Educational – Group E
  • Factory – Group F
  • High Hazard – Groups H-1, H-2, H-3
  • Institutional – Groups I-1, I-2 (both with Conditions 1 and 2)
  • Mercantile – Group M
  • Residential – Groups R-1, R-2, R-3, R-4
  • Storage – Groups S-1, S-2
  • Utility and Miscellaneous – Group U

While occupancy classification is limited to this list, there are essentially an unlimited number of potential uses for a building or space. The use of a space is certainly a factor in determining the occupancy classification, but it is not the only one. Chapter 3 of the IBC has very specific definitions for each occupancy group, and these definitions can result in the occupancy classification of a building or space varying from what might be expected based on the use.

For example, most offices and places of business have conference rooms, where multiple people come together for meetings, presentations or collaboration. The use of such spaces might lead you to think that the conference room is an assembly occupancy. But per IBC 303.1, if your office has a conference room with 49 people, the conference room is considered a business occupancy. There are many similar examples where the use of a space does not necessarily align with the occupancy, so always refer to the definitions in Chapter 3 when determining the occupancy classification.

Now getting back to the original discussion, “mixed use buildings” do not have specific requirements because nearly every building contains multiple uses. Does your office suite have a storage area? You have at least two uses there. Does your retail store have an office in the back? Multiple uses. Does your apartment building contain an amenity space? You get the point.

So when people use the term “mixed-use,” it doesn’t mean much from a code standpoint, and practically, almost all buildings contain multiple uses. But what most folks intend to convey by this term is that the building has at least two distinct occupancy types, which the IBC would consider “mixed occupancy.” And unlike “mixed-use,” there are numerous requirements for “

mixed occupancy

buildings” in the IBC. In fact, IBC Chapter 5 has sections for allowable height, allowable area, allowable number of stories and required separation of occupancy, all of which are impacted when a building is mixed occupancy.

Conclusion

Conversationally, “mixed use building” is generally understood to mean a building containing multiple occupancy types. Architects, engineers, contractors and code officials all use this term and it typically does not create a misunderstanding. But as far as the code language goes, mixed use doesn’t mean anything for the requirements for a building. Mixed occupancy, on the other hand, carries many code requirements that must be understood for a code-compliant building design.

*While IBC 508 is entitled "Mixed Use and Occupancy,' it does not actually have specificrequirementsfor mixed use buildings, only mixed occupancy buildings.

Need assistance on your specific project?

Add Campbell Code Consulting to your team. They are a full-service code consulting and fire protection engineering firm that can help you navigate complex code challenges.

Contact Us

10/14/2021 12:02:08 am

What an exquisite article! Your post is very helpful right now. Thank you for sharing this informative one.
If you are looking for coupon codes and deals just visit coupon plus deals dot

Reply

4/29/2022 10:37:44 pm

What an exquisite article! Your post is very helpful right now. Thank you for sharing this informative one.
If you are looking for coupon codes and deals just visit coupon plus deals dot com

Reply

7/19/2022 08:48:14 pm

This is a very informative—edifying article to all. Thanks a lot! Continue to post!
If you are looking for coupon codes and deals just visit coupon plus deals dot com

Reply

Cheddar

8/1/2022 11:45:35 am

"But per IBC 303.1, if your office has a conference room with 49 people, the conference room is considered a business occupancy. There are many similar examples where the use of a space does not necessarily align with the occupancy, so always refer to the definitions in Chapter 3 when determining the occupancy classification"

Will this apply to egress calculation also? or just construction?
For example, it won't apply to creating fire separations (bc of size/occupant load), but should the conf. room load be calculated as 150/gross vs. 15/net when estimating egress? (or plumbing fixtures?)

Reply

This is a great article. The quality of your writing is impressive. Keep it up.

Reply

Mixed Use Buildings (2024)
Top Articles
How to hard refresh your browser Chrome, Firefox, Safari
Is It Necessary To Have An Air Purifier In Every Room?
Hotels Near 6491 Peachtree Industrial Blvd
Libiyi Sawsharpener
Zabor Funeral Home Inc
Es.cvs.com/Otchs/Devoted
Delectable Birthday Dyes
The Many Faces of the Craigslist Killer
You can put a price tag on the value of a personal finance education: $100,000
Epaper Pudari
Facebook Marketplace Charlottesville
Craigslist Pets Southern Md
Morocco Forum Tripadvisor
Sarpian Cat
Hair Love Salon Bradley Beach
I Wanna Dance with Somebody : séances à Paris et en Île-de-France - L'Officiel des spectacles
Alejos Hut Henderson Tx
Pricelinerewardsvisa Com Activate
Q Management Inc
Powerball winning numbers for Saturday, Sept. 14. Check tickets for $152 million drawing
Comics Valley In Hindi
White Pages Corpus Christi
Where Is The Nearest Popeyes
Van Buren County Arrests.org
Craigs List Tallahassee
Who is Jenny Popach? Everything to Know About The Girl Who Allegedly Broke Into the Hype House With Her Mom
MyCase Pricing | Start Your 10-Day Free Trial Today
Kirsten Hatfield Crime Junkie
Sams Gas Price Sanford Fl
Downtown Dispensary Promo Code
Restored Republic
3 Ways to Format a Computer - wikiHow
ATM, 3813 N Woodlawn Blvd, Wichita, KS 67220, US - MapQuest
Wells Fargo Bank Florida Locations
"Pure Onyx" by xxoom from Patreon | Kemono
Eaccess Kankakee
Marine Forecast Sandy Hook To Manasquan Inlet
Ny Post Front Page Cover Today
Bimmerpost version for Porsche forum?
SF bay area cars & trucks "chevrolet 50" - craigslist
“Los nuevos desafíos socioculturales” Identidad, Educación, Mujeres Científicas, Política y Sustentabilidad
Cuckold Gonewildaudio
Craigslist Antique
Academic Notice and Subject to Dismissal
BCLJ July 19 2019 HTML Shawn Day Andrea Day Butler Pa Divorce
Trending mods at Kenshi Nexus
3500 Orchard Place
Costner-Maloy Funeral Home Obituaries
15:30 Est
Latest Posts
Article information

Author: Sen. Ignacio Ratke

Last Updated:

Views: 5926

Rating: 4.6 / 5 (56 voted)

Reviews: 95% of readers found this page helpful

Author information

Name: Sen. Ignacio Ratke

Birthday: 1999-05-27

Address: Apt. 171 8116 Bailey Via, Roberthaven, GA 58289

Phone: +2585395768220

Job: Lead Liaison

Hobby: Lockpicking, LARPing, Lego building, Lapidary, Macrame, Book restoration, Bodybuilding

Introduction: My name is Sen. Ignacio Ratke, I am a adventurous, zealous, outstanding, agreeable, precious, excited, gifted person who loves writing and wants to share my knowledge and understanding with you.